Les outils du Lean Manufacturing
Company : unknown   Account : guest   Identify here
Corporate LeanTek and
Lean-Manufacturing
Picture Gallery LeanTek®
components / uses
Trilogiq services Delivery options Help with assembly Technical
specifications
 
 
Technical specifications Tube strength  
Load characteristics for joints
Tube deflection
Tube strength
Roller track strength
Cliquez ici  
 
Maximum permissible loads for a standard T1 tube with 1 mm walls in deflection only
 
 
Test method.
 
Distance between supports (m)
Weight limits ( Kg )   0.75 1.0 1.25 1.50 1.75 2.0 2.25 2.50
Before irreversible deflection   90.1 67.6 54.1 45.1 38.6 33.8 30.0 27.0
Before failure   115 86.0 6808 57.3 49.2 43.0 38.2 34.4
 
Deflection in mm of a standard T1 tube with 1 mm walls when subjected to a central load
 
Distance between supports ( m )
    0.75 1.0 1.25 1.50 1.75 2.0 2.25 2.5
Suspended 10 Kg 0.91 2.2 4.2 7.3 11.5 17 25 34
weight 25 Kg 2.3 5.4 10.5 18 29 43 61 84
  50 Kg 4.5 10.8 21 36        
  75 Kg 6.8              
 
Maximum permissible loads for a standard T2 tube with 2 mm walls in deflection only
 
Distance between supports ( m )
Weight limits ( Kg )   0.75 1.0 1.25 1.50 1.75 2.0 2.25 2.50
Before irreversible deflection   205 154 123 102 87.8 76.8 68.3 61.5
Before failure   244 183 146 122 105 91.5 81.3 71.2
 
Deflection in mm of a standard T2 tube with 2 mm walls when subjected to a central load
 
Distance between supports ( m )
    0.75 1.0 1.25 1.50 1.75 2.0 2.25 2.5
Suspended 10 Kg 0.51 1.2 2.4 4.1 6.5 9.6 14 19
weight 25 Kg 1.3 3.0 5.9 10.2 16 24 34 47
  50 Kg 2.5 6.0 11.8 20 32 48 69 94
  75 Kg 3.8 9.0 18 30 48 72    
  100 Kg 5.1 12 24 41        
  125 Kg 6.4 15 30          
 
     
     
 
©1999 - 2005 TRILOGIQ SA - eStudio development